Walk On Water designs
Peter Hostetler
Electrical
  SYSTEM LOADS               
  SYSTEM COLUMN A COLUMN B COLUMN C          
  FRESH WATER 0.00 0.07 0.00      
  GRAY WATER 0.00 6.07 0.00      
  BLACK WATER 0.00 6.07 0.00      
  FUEL 0.00 0.00 0.00   COLUMN A=CRITICAL LOADS    
  BILGE 7.07 0.00 0.00   COLUMN B=AC/DC LOADS    
  ELECTRONICS 0.00 0.00 27.00   COLUMN C=LARGE LOADS THAT NEVER RUN SOLELY ON BATTERY IF AT ALL.    
  VENTILATION 0.00 0.00 0.00      
  NAVIGATION & CONTROLS 4.79 0.00 0.00      
  GALLEY 0.00 0.00 0.00      
  LIGHTING 0.00 7.54 0.00      
  ACCESSORIES 0.00 0.00 0.00      
  TOTALS 11.86 19.75 27.00          
  CONDITIONS              
  SCENARIO 1 SCENARIO 2 SCENARIO 3  
  NUMBER OF DAYS 3 NUMBER OF DAYS 0 NUMBER OF DAYS 0  
  HOURS PER DAY 24 HOURS PER DAY 0 HOURS PER DAY 0  
  LOADS PER DAY LOADS PER DAY LOADS PER DAY  
  FRESH WATER 1.68 FRESH WATER 0.00 FRESH WATER 0.00  
  GRAY WATER 2.28 GRAY WATER 0.00 GRAY WATER 0.00  
  BLACK WATER 2.28 BLACK WATER 0.00 BLACK WATER 0.00  
  FUEL 0.00 FUEL 0.00 FUEL 0.00  
  BILGE 3.43 BILGE 0.00 BILGE 0.00  
  ELECTRONICS 0.00 ELECTRONICS 0.00 ELECTRONICS 0.00  
  VENTILATION 0.00 VENTILATION 0.00 VENTILATION 0.00  
  NAVIGATION & CONTROLS 12.10 NAVIGATION & CONTROLS 0.00 NAVIGATION & CONTROLS 0.00  
  GALLEY 0.00 GALLEY 0.00 GALLEY 0.00  
  LIGHTING 7.51 LIGHTING 0.00 LIGHTING 0.00  
  ACCESSORIES 0.00 ACCESSORIES 0.00 ACCESSORIES 0.00  
  TOTAL 29.28 TOTAL 0.00 TOTAL 0.00  
  NOTES: 1 DAY DEFINED AS 24 HOURS ON BOAT AWAY FROM DOCK SAILING FOR 8  WITH REGULAR CRUISING LOADS AS DEFINED BY THE AMOUNT OF TIME GIVEN FOR ITEMS IN PREVIOUS SPREADSHEETS.   NOTES:   NOTES:     
   
   
   
   
  REQUIRED BATTERY CAPACITIES            
  SCENARIO  AMP HOURS RES MIN SURGE LOAD MCA AMP HOURS=AMP HOURS DRAWN PER DAY MULTIPLIED NUMBER OF DAYS MULTIPLIED BY 2.   
  1 175.66 36.26 97.03 MINIMAL  
  2 0.00 36.26 97.03 MINIMAL RES MIN=SEE ABYC E-11.7.1.1.2  
  3 0.00 36.26 97.03 MINIMAL SURGE LOAD=REQUIRED AMP HOURS SO THAT COLUMN A + THE LARGER OF 10% COLUMN B OR SINGLE GREATEST LOAD DOES NOT EXCEED 20% OF THE BATTERY'S AMP HOURS.  
  MET OK OK OK OK  
  MCA=AS PER ENGINE MANUFACTURER SPECIFICATIONS.  
  SUPPLIED BATTERY CAPACITIES            
  SIZE TYPE MANUFACTURER AH RES MIN MCA      
  GP 31 AGM LIFELINE 105.00 195.00 750.00    
  GP 31 AGM LIFELINE 105.00 195.00 750.00    
  TOTAL 210.00 390.00 750.00      
  PANEL LOADS              
    AC MAIN AC LOW 24 HOUR DC MAIN  
    BREAKER AMPS BREAKER AMPS BREAKER AMPS BREAKER AMPS  
    OUTLETS 25.00 N/A 0.00 BILGE 7.07 FW 0.07  
    CHARGER 2.00 N/A 0.00 OPEN 0.00 GW 6.07  
    OPEN 0.00 N/A 0.00 OPEN 0.00 BW 6.07  
    N/A 0.00 N/A 0.00 OPEN 0.00 NAV LIGHTS 2.50  
    N/A 0.00 N/A 0.00 OPEN 0.00 NAVIGATION 2.29  
    N/A 0.00 N/A 0.00 OPEN 0.00 LIGHTS 7.50  
    N/A 0.00 N/A 0.00 N/A 0.00 COCKPIT 0.04  
    N/A 0.00 N/A 0.00 N/A 0.00 OPEN 0.00  
    N/A 0.00 N/A 0.00 N/A 0.00 OPEN 0.00  
    N/A 0.00 N/A 0.00 N/A 0.00 OPEN 0.00  
  TOTAL   27.00   0.00   7.07   24.55  
  DISTRIBUTION DETAILS              
  AC MAIN OUTLETS OUTLET IN HEAD DC MAIN FW GAUGE  
  OUTLET IN GALLEY GW GAUGE  
  OPEN FREE BREAKER DIAPHRAGM PUMP  
  OPEN FREE BREAKER BW GAUGE  
  24 HOUR PANEL BILGE BILGE PUMP DIAPHRAGM PUMP  
  BILGE SWITCH NAV LIGHTS STERN  
  OPEN FREE BREAKER 360 DEGREE  
  OPEN FREE BREAKER BI COLOR  
  OPEN FREE BREAKER NAVIGATION WIND/DEPTH/DIRECTION INSTRUMENT  
  OPEN FREE BREAKER VHF RADIO  
  OPEN FREE BREAKER LIGHTS INTERIOR RECESSED LIGHTING  
    COCKPIT ONE LED LIGHT  
    OPEN FREE BREAKER  
    OPEN FREE BREAKER  
          OPEN FREE BREAKER